美国Hausser scientific血球计数板
产品简介
美国Hausser scientific血球计数板
美国Hausser scientific血球计数板
上海上碧实验仪器有限公司
详细信息
产品特点:
l 美国Hausser scientific血球计数板,准确计算白细胞、红细胞、血小板、组织培养细胞、细菌和精子
l H形两个计数区,V型斜槽防止液体溢出
l When viewed through a microscope, hemacytometers display white Neubauer markings against a dark background. Choose from Bright-Line® hemacytometers with a Pyrex® surface or Hy-lite hemacytometers with a milled glass surface. Bright-Line phase contrast hemacytometer is thinner—ideal for use with phase contrast microscopes. Glass coverslips cover moat region 0.1 mm above ruled surface, limiting volume to 0.1 mm3
货号 | 产品描述 |
3100 | 美国Hausser scientific血球计数板 |
| HEMACYTOMETER HY-LITE血球计数板 |
| HEMACYTOMETER PHASE CONTRAST血球计数板 |
| HEMACYTOMETER盖玻片 |
3110 | Hemacytometer hy-lite血球计数板, counting chamber |
The Bright-Line Hemacytometer is of one piece construction, ensuring long term durability and accuracy. An H-shaped moat forms two counting areas, or plateaus. A "V" slash at the loading side of each plateau facilitates charing and reduces the possibility of overflow into the moat. Each plateau features enhanced Neubauer rulings. The ruled surface is 0.1mm below the cover glass, limiting the volume of blood or fluid over a square mm at 0.1cu.mm and over each of 400 squares (within the central square mm) to 0.00025 cu. mm. Contact of the flat, polished cover glass surfaces with cover glass supports produces an exact volume of fluid over the counting area. The difference in surface tension characteristics between the metallic surface on the chamber and the polished cover glass assures smooth capillarity for precise loading and more even cell distribution.
Directions for Use
Bright-Line / Dark-Line Counting Chambers Catalog Numbers: 3100, 3110, 3200, 3500, 1490, 1492, 1475, & 1483
Usage: Cell Counts
Cell Depth: 0.100mm +/- 2% (1/10mm)
Volume: 0.1 Microliter
Ruling Pattern: Improved Neubauer, 1/400 Square mm
Rulings cover 9 square millimeters. Boundary lines of the Neubauer ruling are the center lines of the groups of three. (These are indicated in the illustration below.) The central square millimeter is ruled into 25 groups of 16 small squares, each group separated by triple lines, the middle one of which is the boundary. The ruled surface is 0.10mm below the cover glass, so that the volume over each of the 16 small squares is .00025 cubic mm.
The number of cells per cubic millimeter =
Number of cells counted per square millimeter X dilution (if used) X 10
The number of cells per milliliter =
Number of cells counted per square millimeter X dilution (if used) X 10,000
One (1) Milliliter = 1000 cubic millimeters (cu mm)
One (1) Microliter (ul) = One (1) cubic millimeter (cu mm)
To clean the counting chamber: After completing the count, remove the cover glass and clean the counting chamber with water or a mild cleaning solution (10% solution of bleach). Dry the counting chamber with a soft cloth or wipe, or rinse with acetone.
l Cells per ml = Average count per square x dilution factor x 10,000
美国Hausser scientific血球计数板
美国Hausser scientific血球计数板
美国Hausser scientific血球计数板