恒温恒湿试验箱循环试验失效原因解析

Constant temperature and humidity test chamber also known as "high low temperature alternating test chamber", based on inligent instrument, screen can be set program loop test, in test phase, there is a cycling test fails, the following by the constant temperature and humidity test chamber production experts - Beijing hong da day torque test equipment co., LTD., analyzes the failure reason:
1, the basic parameters: the temperature cyclic stress mainly has six basic parameters:
(1) ceiling temperature;
(2) the lower temperature;
(3) temperature change rate;
(4) limit temperature holding time;
(5) the lower temperature holding time; 6 cycles.
2, temperature cycle stress characteristic: in the temperature cycling test, constant temperature and humidity test in the airflow uniformity is an important parameter, this parameter will influence the temperature change rate of the products.

     恒温恒湿试验箱 又名“高低温湿热交变试验箱”,采用触摸屏智能型仪表,可设定程序循环试验,在试验进行阶段,有一种循环试验失效,下面由恒温恒湿试验箱生产专家-北京鸿达天矩试验设备有限公司对失效原因进行分析:

1、温度循环应力基本参数:基本参数主要有6个:①上限温度;②下限温度;③温度变化速率;④上限温度保温时间;⑤下限温度保温时间;⑥循环次数。

2、温度循环应力特性分析:在温度循环试验中,恒温恒湿试验箱内的气流均匀度是一个很重要的参数,该参数将影响产品的温度变化速率。这就要求在多个试验产品同时进行试验时,试验产品之间、试验产品和试验箱壁之间应有适当的间隔,以便气流能在试验产品之间、试验产品和箱壁之间自由循环。

3、温度循环应力诱发失效的机理及敏感元件:温度循环使不同膨胀系数的不同材料的膨胀情况不同,造成剥离、开裂、其敏感元件如油漆涂覆层等。

3.1温度循环使螺丝连接或铆接不牢的接头松驰,其敏感元件如螺丝、铆接部件等;

3.2温度循环使机械张力不足的压配接头松驰;高低温交变试验箱温度循环使材质差的钎焊接触电阻加大或诱发开路,其敏感元件如电阻元件等;

3.3温度循环使触点腐蚀和污染,其敏感元件如合金材料等。

 