843经济便携型功率计

843经济便携型功率计

参考价: 面议

具体成交价以合同协议为准
2024-06-06 15:02:19
87
产品属性
关闭
北京纽比特科技有限公司

北京纽比特科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

详细介绍



843经济便携型功率计


 

Sampling Rate 15 Hz
Display Refresh Rate 15 Hz
Display Type High legibility TFT 320 x 240 pixel graphics LCD
Display 15 mm numeric display. High resolution analog needle also can be chosen.
Compatible Detectors 详询销售工程师
Detector Type Low Power, High Power, Energy
Detector Input Up to 1.3 mA for Photodiode Sensors
Accuracy ±0.25 % (Full Scale) ± 20 p A
Maximum Detector Input Current 1.4 mA
Maximum Input Power Detector dependent
Resolution 18 bits plus sign
Wavelength Range Detector dependent
Analog Output 0-1 V into 100 Ω, mono audio 2.5 mm jack (included)
Communication Interfaces None
Data Storage None
Battery Life 14 hours typical between charges.
Battery Rechargeable Li-ion Batteries
Power Requirements DC 12 - 16 V, 1W
Length 40 mm ( 1.6 in.)
Height 8.4 in. ( 213 mm)
Width 4.4 in. ( 113 mm)
Weight 1.0 lb ( 0.47 kg)
RoHS Compliant
CE Certified

Yes

 

常用配置参数

Wavelength Range 190 to 10,60nm
Power Range 1 mW - 10 W
Pulse Energy, Maximum - w/o Attenuator 1 nJ/cm2
Calibration Uncertainty 3 %
Calibration Uncertainty, w/ Attenuator N/A

 

选配探头:

Model红外探头1

Spectral Range780 to 1800 nm

Max. Measurable Power2 W

Max. Measurable Power w/o Attenuator10 mW

Pulse Energy Density, Maximum - w/o Attenuator5 µJ/cm2

Active Diameter0.3 cm

Detector Active Area0.071 cm2

Power Density, Maximum Average30 W/cm2

Pulse Energy, Maximum - w/ Attenuator5 u J

Pulse Energy, Maximum - w/o Attenuator5 n J

MaterialGermanium

Uniformity±2 %

Calibration Uncertainty2% @ 780-910nm, 2% @ 911-1700nm, 4%@1701-1800 nm

Calibration Uncertainty, w/ Attenuator5% @ 780-910nm, 2% @ 911-1700nm, 4% @ 1701-1800 nm

Minimum Detectable Power5 n W

Pulse Energy Density, Maximum - w/ Attenuator5 mJ/cm2

Linearity±0.5 %

Model红外探头2

Spectral Range780 to 1800 nm

Max. Measurable Power2 W

Max. Measurable Power w/o Attenuator5 mW

Pulse Energy Density, Maximum - w/o Attenuator5 nJ/cm2

Connector TypeDB15 - Newport Compatible

Active Diametersquare 1 x 1 cm

Detector Active Area1 cm2

Power Density, Maximum Average30 W/cm2

Pulse Energy, Maximum - w/ Attenuator0.35 u J/cm2

Pulse Energy, Maximum - w/o Attenuator0.35 nJ/cm2

MaterialGermanium

Uniformity±2 %

Calibration Uncertainty2% @ 780-910nm, 2% @ 911-1700nm

4%@1701-1800 nm

Calibration Uncertainty, w/ Attenuator5% @ 780-910nm, 2% @ 911-1700nm

4% @ 1701-1800 nm

Pulse Energy Density, Maximum - w/ Attenuator5 µJ/cm2

Linearity±0.5 %

更多探头选配,请详询销售工程师

 



上一篇:南京工业大学陈峰教授:钙钛矿材料的最新研究成果解析 下一篇:专访徐鹏:探索阿秒科学,揭示光的奥秘
提示

请选择您要拨打的电话: